Standard design for National Ignition Facility x-ray streak and framing cameras

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.3496990· OSTI ID:1124976
The x-ray streak camera and x-ray framing camera for the National Ignition Facility were redesigned to improve electromagnetic pulse hardening, protect high voltage circuits from pressure transients, and maximize the use of common parts and operational software. Both instruments use the same PC104 based controller, interface, power supply, charge coupled device camera, protective hermetically sealed housing, and mechanical interfaces. Communication is over fiber optics with identical facility hardware for both instruments. Each has three triggers that can be either fiber optic or coax. High voltage protection consists of a vacuum sensor to enable the high voltage and pulsed microchannel plate phosphor voltage. In the streak camera, the high voltage is removed after the sweep. Both rely on the hardened aluminum box and a custom power supply to reduce electromagnetic pulse/electromagnetic interference (EMP/EMI) getting into the electronics. In addition, the streak camera has an EMP/EMI shield enclosing the front of the streak tube.
Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
1124976
Report Number(s):
LLNL-JRNL--458472
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 10 Vol. 81; ISSN 0034-6748
Publisher:
American Institute of Physics (AIP)
Country of Publication:
United States
Language:
English

References (4)

National Ignition Facility core x-ray streak camera journal January 2001
The National Ignition Facility: Laser Performance and First Experiments journal April 2005
Gated x-ray detector for the National Ignition Facility journal October 2006
Characterization of the series 1000 camera system journal October 2004

Similar Records

Standard design for National Ignition Facility x-ray streak and framing cameras
Journal Article · Fri Oct 15 00:00:00 EDT 2010 · Review of Scientific Instruments · OSTI ID:22055900

Characterization of the Series 1000 Camera System
Conference · Wed Apr 07 00:00:00 EDT 2004 · OSTI ID:892780

Characterization of the series 1000 camera system
Journal Article · Fri Oct 01 00:00:00 EDT 2004 · Review of Scientific Instruments · OSTI ID:20641232

Related Subjects