Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Compressive sensing for nuclear security

Technical Report ·
DOI:https://doi.org/10.2172/1121944· OSTI ID:1121944
 [1]
  1. Sandia National Lab. (SNL-CA), Livermore, CA (United States)

Special nuclear material (SNM) detection has applications in nuclear material control, treaty verification, and national security. The neutron and gamma-ray radiation signature of SNMs can be indirectly observed in scintillator materials, which fluoresce when exposed to this radiation. A photomultiplier tube (PMT) coupled to the scintillator material is often used to convert this weak fluorescence to an electrical output signal. The fluorescence produced by a neutron interaction event differs from that of a gamma-ray interaction event, leading to a slightly different pulse in the PMT output signal. The ability to distinguish between these pulse types, i.e., pulse shape discrimination (PSD), has enabled applications such as neutron spectroscopy, neutron scatter cameras, and dual-mode neutron/gamma-ray imagers. In this research, we explore the use of compressive sensing to guide the development of novel mixed-signal hardware for PMT output signal acquisition. Effectively, we explore smart digitizers that extract sufficient information for PSD while requiring a considerably lower sample rate than conventional digitizers. Given that we determine the feasibility of realizing these designs in custom low-power analog integrated circuits, this research enables the incorporation of SNM detection into wireless sensor networks.

Research Organization:
Sandia National Laboratories (SNL-CA), Livermore, CA (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
1121944
Report Number(s):
SAND2013--10506; 492705
Country of Publication:
United States
Language:
English

Similar Records

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications
Technical Report · Mon Oct 12 00:00:00 EDT 2020 · OSTI ID:1682525

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications
Conference · Mon Nov 30 23:00:00 EST 2020 · Proceedings of the INMM 61st Annual Meeting · OSTI ID:1755845

Evaluation of a positron-emission-tomography-based SiPM readout for compact segmented neutron imagers
Journal Article · Mon Oct 31 00:00:00 EDT 2022 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1989460