Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Measurements of Ionizing Radiation Doses Induced by High Irradiance Laser on Targets in LCLS MEC Instrument

Technical Report ·
DOI:https://doi.org/10.2172/1120134· OSTI ID:1120134
Comprehensive measurements for photon and neutron radiation doses generated from laser-plasma interaction at SLAC’s MEC laser facility have been conducted. The goals of the measurements were to; determine the radiation dose per laser shot as a function of laser, optic and target parameters that are relevant to the MEC laser operations; validate the RPD-developed analytic model for photon dose calculations; and evaluate the performance of various types of passive and active detectors in the laser-induced radiation fields.
Research Organization:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Organization:
USDOE Office of Science (SC)
DOE Contract Number:
AC02-76SF00515
OSTI ID:
1120134
Report Number(s):
SLAC-PUB--15889
Country of Publication:
United States
Language:
English

Similar Records

Measurements of Ionizing Radiation Doses Induced by High Irradiance Laser on Targets in LCLS MEC Instrument - Paper 75
Conference · Mon Sep 15 00:00:00 EDT 2014 · OSTI ID:23082908

Radiation Dose Measurement for High-Intensity Laser Interactions with Solid Targets at SLAC
Journal Article · Fri Sep 25 00:00:00 EDT 2015 · Radiation Protection Dosimetry · OSTI ID:1221586

Shielding Calculations for the Hard X-Rays Generated by LCLS Mec Laser System