Correction of the Triplet Skew Quadrupole Errors in RHIC
- Brookhaven National Lab. (BNL), Upton, NY (United States)
This study explores the possibility of operating the present RHIC coupling correction system in local decoupling mode, where a subset of skew quadrupoles are independently set by minimizing the coupling as locally measured by beam position monitors.
- Research Organization:
- Brookhaven National Lab. (BNL), Upton, NY (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC)
- DOE Contract Number:
- AC02-98CH10886
- OSTI ID:
- 1119452
- Report Number(s):
- BNL--102167-2013-IR
- Country of Publication:
- United States
- Language:
- English
Similar Records
The effect and correction of coupling generated by the RHIC triplet quadrupoles
Skew quadrupole errors in the RHIC IR triplets