skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Peak Loop Pressure and Peak Temperature in the MAGCOOL-Subcooler Cryogenic System after Low Current Quenches of SSC Dipole DCA213

Technical Report ·
DOI:https://doi.org/10.2172/1119173· OSTI ID:1119173
 [1]
  1. Brookhaven National Lab. (BNL), Upton, NY (United States)

The performance of the MAGCOOL cryogenic system after 2500, 3000, and 3500 ampere srip heater quenches of SSC dipole DCA213 was investigated to confirm that the peak pressure and temperature in the magnet cooling loop are linearly proportional to the energy released during a quench.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
USDOE Office of Science (SC)
DOE Contract Number:
AC02-98CH10886
OSTI ID:
1119173
Report Number(s):
BNL-101831-2013-IR
Country of Publication:
United States
Language:
English