Peak Loop Pressure and Peak Temperature in the MAGCOOL-Subcooler Cryogenic System after Low Current Quenches of SSC Dipole DCA213
- Brookhaven National Lab. (BNL), Upton, NY (United States)
The performance of the MAGCOOL cryogenic system after 2500, 3000, and 3500 ampere srip heater quenches of SSC dipole DCA213 was investigated to confirm that the peak pressure and temperature in the magnet cooling loop are linearly proportional to the energy released during a quench.
- Research Organization:
- Brookhaven National Lab. (BNL), Upton, NY (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC)
- DOE Contract Number:
- AC02-98CH10886
- OSTI ID:
- 1119173
- Report Number(s):
- BNL-101831-2013-IR
- Country of Publication:
- United States
- Language:
- English
Similar Records
Peak loop pressure and temperature and comparison of total cooling provided to the energy released after low current quenches of SSC dipoles in magcool cryogenic system
Performance of the MAGCOOL-subcooler cryogenic system after SSC quadrupole quenches
Performance of the MAGCOOL-subcooler cryogenic system after SSC quadrupole quenches
Conference
·
Sat Dec 31 00:00:00 EST 1994
·
OSTI ID:1119173
Performance of the MAGCOOL-subcooler cryogenic system after SSC quadrupole quenches
Conference
·
Tue Jun 01 00:00:00 EDT 1993
·
OSTI ID:1119173
Performance of the MAGCOOL-subcooler cryogenic system after SSC quadrupole quenches
Conference
·
Fri Jan 01 00:00:00 EST 1993
·
OSTI ID:1119173