Comparisons of NIF convergent ablation simulations with radiograph data
A technique for comparing simulation results directly with radiograph data from backlit capsule implosion experiments will be discussed. Forward Abel transforms are applied to the kappa*rho profiles of the simulation. These provide the transmission ratio (optical depth) profiles of the simulation. Gaussian and top hat blurs are applied to the simulated transmission ratio profiles in order to account for the motion blurring and imaging slit resolution of the experimental measurement. Comparisons between the simulated transmission ratios and the radiograph data lineouts are iterated until a reasonable backlighter profile is obtained. This backlighter profile is combined with the blurred, simulated transmission ratios to obtain simulated intensity profiles that can be directly compared with the radiograph data. Examples will be shown from recent convergent ablation (backlit implosion) experiments at the NIF.
- Sponsoring Organization:
- USDOE
- Grant/Contract Number:
- AC04-94AL85000
- OSTI ID:
- 1114956
- Journal Information:
- Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 10 Vol. 83; ISSN 0034-6748
- Publisher:
- American Institute of PhysicsCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Similar Records
Measurement of mix at the fuel–ablator interface in indirectly driven capsule implosions on the National Ignition Facility
Design calculations for NIF convergent ablator experiments.