Moisture performance of sealed attics in the mixed-humid climate
- Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Oak Ridge National Laboratory studied 8 homes in the mixed-humid climate, 4 with vented attics and 4 with sealed attics. ORNL wanted to understand the moisture performance of the sealed attic and how it affected the interior environment. We found that the attic and interior of sealed attic homes were more humid than the attic and interior observed in vented attic homes. This is due to the lack of ventilation in the sealed attic. Historically attics have been vented to dehumidify the attic and interior of the home. A sealed attic design greatly reduces the venting potential and thus this drying pathway and can cause elevated interior moisture over a vented attic home. Despite the elevated attic and interior moisture in the sealed attic homes, so far no mold or material degradation has been found. The roof sheathing moisture content has stayed below 20%, indicating low potential for material degradation. Also the relative humidity at the roof sheathing has stayed within the ASHRAE 160 design criteria except for a short time during the 2011/2012 winter. This was due to a combination of the sealed attic design (minimal venting to the outside) and the duct work not being operated in the attic which usually provides a dehumidification pathway. It was also found that when the humidity was controlled using the HVAC system, it resulted in 7% more cooling energy consumption. In the mixed-humid climate this reduces the cost effectiveness of the sealed attic design as a solution for bringing ducts into a semi-conditioned space. Because of this we are recommending the other alternatives be used to bringing ducts into the conditioned space in both new construction and retrofit work in the mixed-humid climate.
- Research Organization:
- Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Building Technologies Research and Integration Center
- Sponsoring Organization:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE)
- DOE Contract Number:
- AC05-00OR22725
- OSTI ID:
- 1113688
- Report Number(s):
- ORNL/TM--2013/525; BT0201000; CEBT114
- Country of Publication:
- United States
- Language:
- English
Similar Records
Indoor Climate and Moisture Durability Performances of Houses with Unvented Attic Roof Constructions in a Mixed-Humid Climate
A Literature Review of Sealed and Insulated Attics—Thermal, Moisture and Energy Performance
Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates
Technical Report
·
Wed Oct 01 00:00:00 EDT 2014
·
OSTI ID:1185718
A Literature Review of Sealed and Insulated Attics—Thermal, Moisture and Energy Performance
Technical Report
·
Mon Aug 01 00:00:00 EDT 2016
·
OSTI ID:1340304
Moisture Performance of Unvented Attics With Vapor Diffusion Ports and Buried Ducts in Hot, Humid Climates
Technical Report
·
Sun Sep 01 00:00:00 EDT 2024
·
OSTI ID:2447466