Title: MIXING STUDY FOR JT-71/72 TANKS

Abstract

All modeling calculations for the mixing operations of miscible fluids contained in HBLine tanks, JT-71/72, were performed by taking a three-dimensional Computational Fluid Dynamics (CFD) approach. The CFD modeling results were benchmarked against the literature results and the previous SRNL test results to validate the model. Final performance calculations were performed by using the validated model to quantify the mixing time for the HB-Line tanks. The mixing study results for the JT-71/72 tanks show that, for the cases modeled, the mixing time required for blending of the tank contents is no more than 35 minutes, which is well below 2.5 hours of recirculation pump operation. Therefore, the results demonstrate the adequacy of 2.5 hours’ mixing time of the tank contents by one recirculation pump to get well mixed.

Authors:
Publication Date:
Research Org.:
SRS
Sponsoring Org.:
USDOE
OSTI Identifier:
1108432
Report Number(s):
SRNL-STI-2013-00702
DOE Contract Number:  
DE-AC09-08SR22470
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
42 ENGINEERING; Tank Mixing, Pump Circulation, SpeciesTransport

Citation Formats

Lee, S. MIXING STUDY FOR JT-71/72 TANKS. United States: N. p., 2013. Web. doi:10.2172/1108432.
Lee, S. MIXING STUDY FOR JT-71/72 TANKS. United States. doi:10.2172/1108432.
Lee, S. Tue . "MIXING STUDY FOR JT-71/72 TANKS". United States. doi:10.2172/1108432. https://www.osti.gov/servlets/purl/1108432.
@article{osti_1108432,
title = {MIXING STUDY FOR JT-71/72 TANKS},
author = {Lee, S.},
abstractNote = {All modeling calculations for the mixing operations of miscible fluids contained in HBLine tanks, JT-71/72, were performed by taking a three-dimensional Computational Fluid Dynamics (CFD) approach. The CFD modeling results were benchmarked against the literature results and the previous SRNL test results to validate the model. Final performance calculations were performed by using the validated model to quantify the mixing time for the HB-Line tanks. The mixing study results for the JT-71/72 tanks show that, for the cases modeled, the mixing time required for blending of the tank contents is no more than 35 minutes, which is well below 2.5 hours of recirculation pump operation. Therefore, the results demonstrate the adequacy of 2.5 hours’ mixing time of the tank contents by one recirculation pump to get well mixed.},
doi = {10.2172/1108432},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Nov 26 00:00:00 EST 2013},
month = {Tue Nov 26 00:00:00 EST 2013}
}

Technical Report:

Save / Share: