skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Experimental validation of a high voltage pulse measurement method.

Technical Report ·
DOI:https://doi.org/10.2172/1096484· OSTI ID:1096484

This report describes X-cut lithium niobates (LiNbO3) utilization for voltage sensing by monitoring the acoustic wave propagation changes through LiNbO3 resulting from applied voltage. Direct current (DC), alternating current (AC) and pulsed voltage signals were applied to the crystal. Voltage induced shift in acoustic wave propagation time scaled quadratically for DC and AC voltages and linearly for pulsed voltages. The measured values ranged from 10 - 273 ps and 189 ps 2 ns for DC and non-DC voltages, respectively. Data suggests LiNbO3 has a frequency sensitive response to voltage. If voltage source error is eliminated through physical modeling from the uncertainty budget, the sensors U95 estimated combined uncertainty could decrease to ~0.025% for DC, AC, and pulsed voltage measurements.

Research Organization:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
DOE Contract Number:
AC04-94AL85000
OSTI ID:
1096484
Report Number(s):
SAND2013-7985; 476227
Country of Publication:
United States
Language:
English

Similar Records

Comparative study of 0° X-cut and Y+36°-cut lithium niobate high-voltage sensing
Journal Article · Tue Aug 11 00:00:00 EDT 2015 · Review of Scientific Instruments · OSTI ID:1096484

Comparative study of 0° X-cut and Y + 36°-cut lithium niobate high-voltage sensing
Journal Article · Sat Aug 15 00:00:00 EDT 2015 · Review of Scientific Instruments · OSTI ID:1096484

Response of dairy cattle to transient voltages and magnetic fields
Journal Article · Sat Jul 01 00:00:00 EDT 1995 · IEEE Transactions on Industry Applications · OSTI ID:1096484

Related Subjects