Online Sensor Calibration Assessment in Nuclear Power Systems
Journal Article
·
· IEEE Instrumentation and Measurement Magazine
Safe, efficient, and economic operation of nuclear systems (nuclear power plants, fuel fabrication and storage, used fuel processing, etc.) relies on transmission of accurate and reliable measurements. During operation, sensors degrade due to age, environmental exposure, and maintenance interventions. Sensor degradation can affect the measured and transmitted signals, including sensor failure, signal drift, sensor response time, etc. Currently, periodic sensor recalibration is performed to avoid these problems. Sensor recalibration activities include both calibration assessment and adjustment (if necessary). In nuclear power plants, periodic recalibration of safety-related sensors is required by the plant technical specifications. Recalibration typically occurs during refueling outages (about every 18 to 24 months). Non-safety-related sensors also undergo recalibration, though not as frequently. However, this approach to maintaining sensor calibration and performance is time-consuming and expensive, leading to unnecessary maintenance, increased radiation exposure to maintenance personnel, and potential damage to sensors. Online monitoring (OLM) of sensor performance is a non-invasive approach to assess instrument calibration. OLM can mitigate many of the limitations of the current periodic recalibration practice by providing more frequent assessment of calibration and identifying those sensors that are operating outside of calibration tolerance limits without removing sensors or interrupting operation. This can support extended operating intervals for unfaulted sensors and target recalibration efforts to only degraded sensors.
- Research Organization:
- Pacific Northwest National Laboratory (PNNL), Richland, WA (US)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC05-76RL01830
- OSTI ID:
- 1091432
- Report Number(s):
- PNNL-SA--93093; NT0107000
- Journal Information:
- IEEE Instrumentation and Measurement Magazine, Journal Name: IEEE Instrumentation and Measurement Magazine Journal Issue: 3 Vol. 16; ISSN 1094-6969
- Publisher:
- IEEE
- Country of Publication:
- United States
- Language:
- English
Similar Records
Calibration Monitoring for Sensor Calibration Interval Extension: Gaps in the Current Science Base
High Accuracy Signal Validation Framework for Sensor Calibration Assessment in NPPs
On-Line Monitoring to Detect Sensor and Process Degradation under Normal Operational Transients - 327
Conference
·
Tue Oct 09 00:00:00 EDT 2012
·
OSTI ID:1092028
High Accuracy Signal Validation Framework for Sensor Calibration Assessment in NPPs
Journal Article
·
Fri Jul 01 00:00:00 EDT 2016
· Transactions of the American Nuclear Society
·
OSTI ID:23042605
On-Line Monitoring to Detect Sensor and Process Degradation under Normal Operational Transients - 327
Conference
·
Thu Jun 15 00:00:00 EDT 2017
·
OSTI ID:23035424