Title: Diagnostic options for radiative divertor feedback control on NSTX-U

Abstract

A radiative divertor technique is used in present tokamak experiments and planned for ITER to mitigate high heat loads on divertor plasma-facing components (PFCs) to prevent excessive material erosion and thermal damage. In NSTX, a large spherical tokamak with lithium-coated graphite PFCs and high divertor heat flux (qpeak ≤ 15 MW/m2), radiative divertor experiments have demonstrated a significant reduction of divertor peak heat flux simultaneously with good core H-mode confinement using pre-programmed D2 or CD4 gas injections. In this work diagnostic options for a new real-time feedback control system for active radiative divertor detachment control in NSTX-U, where steady-state peak divertor heat fluxes are projected to reach 20–30 MW/m2, are discussed. Based on the NSTX divertor detachment measurements and analysis, the control diagnostic signals available for NSTX-U include divertor radiated power, neutral pressure, spectroscopic deuterium recombination signatures, infrared thermography of PFC surfaces, and thermoelectric scrape-off layer current. In addition, spectroscopic “security” monitoring of possible confinement or pedestal degradation is recommended. These signals would be implemented in a digital plasma control system to manage the divertor detachment process via an actuator (impurity gas seeding rate).

Authors:
; ; ; ;
Publication Date:
Research Org.:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1089528
Report Number(s):
LLNL-JRNL-555821
Journal ID: ISSN 0034-6748
DOE Contract Number:  
W-7405-ENG-48
Resource Type:
Journal Article
Journal Name:
Review of Scientific Instruments
Additional Journal Information:
Journal Volume: 83; Journal Issue: 10; Journal ID: ISSN 0034-6748
Publisher:
American Institute of Physics (AIP)
Country of Publication:
United States
Language:
English
Subject:
74 ATOMIC AND MOLECULAR PHYSICS; 70 PLASMA PHYSICS AND FUSION

Citation Formats

Soukhanovskii, V. A., Gerhardt, S. P., Kaita, R., McLean, A. G., and Raman, R. Diagnostic options for radiative divertor feedback control on NSTX-U. United States: N. p., 2012. Web. doi:10.1063/1.4732176.
Soukhanovskii, V. A., Gerhardt, S. P., Kaita, R., McLean, A. G., & Raman, R. Diagnostic options for radiative divertor feedback control on NSTX-U. United States. https://doi.org/10.1063/1.4732176
Soukhanovskii, V. A., Gerhardt, S. P., Kaita, R., McLean, A. G., and Raman, R. 2012. "Diagnostic options for radiative divertor feedback control on NSTX-U". United States. https://doi.org/10.1063/1.4732176. https://www.osti.gov/servlets/purl/1089528.
@article{osti_1089528,
title = {Diagnostic options for radiative divertor feedback control on NSTX-U},
author = {Soukhanovskii, V. A. and Gerhardt, S. P. and Kaita, R. and McLean, A. G. and Raman, R.},
abstractNote = {A radiative divertor technique is used in present tokamak experiments and planned for ITER to mitigate high heat loads on divertor plasma-facing components (PFCs) to prevent excessive material erosion and thermal damage. In NSTX, a large spherical tokamak with lithium-coated graphite PFCs and high divertor heat flux (qpeak ≤ 15 MW/m2), radiative divertor experiments have demonstrated a significant reduction of divertor peak heat flux simultaneously with good core H-mode confinement using pre-programmed D2 or CD4 gas injections. In this work diagnostic options for a new real-time feedback control system for active radiative divertor detachment control in NSTX-U, where steady-state peak divertor heat fluxes are projected to reach 20–30 MW/m2, are discussed. Based on the NSTX divertor detachment measurements and analysis, the control diagnostic signals available for NSTX-U include divertor radiated power, neutral pressure, spectroscopic deuterium recombination signatures, infrared thermography of PFC surfaces, and thermoelectric scrape-off layer current. In addition, spectroscopic “security” monitoring of possible confinement or pedestal degradation is recommended. These signals would be implemented in a digital plasma control system to manage the divertor detachment process via an actuator (impurity gas seeding rate).},
doi = {10.1063/1.4732176},
url = {https://www.osti.gov/biblio/1089528}, journal = {Review of Scientific Instruments},
issn = {0034-6748},
number = 10,
volume = 83,
place = {United States},
year = {2012},
month = {10}
}

Works referenced in this record:

Chapter 4: Power and particle control
journal, June 2007


H mode discharges with feedback controlled radiative boundary in the ASDEX Upgrade tokamak
journal, October 1995


High confinement dissipative divertor operation on Alcator C-Mod
journal, May 1999


Improvement of density control by feedback on Langmuir probe signals in Tore Supra ergodic divertor experiments
journal, May 2000


Divertor power load feedback with nitrogen seeding in ASDEX Upgrade
journal, March 2010


Overview of the physics and engineering design of NSTX upgrade
journal, July 2012


Strike point control for the National Spherical Torus Experiment (NSTX)
journal, September 2010


Spectroscopic diagnostics for liquid lithium divertor studies on National Spherical Torus Experiment
journal, October 2010


Fast neutral pressure gauges in NSTX
journal, October 2004


The experimental determination of the volume recombination rate in tokamak divertors
journal, March 1999


Currents in the scrape-off layer of diverted tokamaks
journal, October 1989