Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

A general unified non-equilibrium model for predicting saturated and subcooled critical two-phase flow rates through short and long tubes

Technical Report ·
DOI:https://doi.org/10.2172/106995· OSTI ID:106995
 [1];  [2]
  1. Univ. of British Columbia (Canada)
  2. Univ. of Toronto, Ontario (Canada)
A general unified model is developed to predict one-component critical two-phase pipe flow. Modelling of the two-phase flow is accomplished by describing the evolution of the flow between the location of flashing inception and the exit (critical) plane. The model approximates the nonequilibrium phase change process via thermodynamic equilibrium paths. Included are the relative effects of varying the location of flashing inception, pipe geometry, fluid properties and length to diameter ratio. The model predicts that a range of critical mass fluxes exist and is bound by a maximum and minimum value for a given thermodynamic state. This range is more pronounced at lower subcooled stagnation states and can be attributed to the variation in the location of flashing inception. The model is based on the results of an experimental study of the critical two-phase flow of saturated and subcooled water through long tubes. In that study, the location of flashing inception was accurately controlled and adjusted through the use of a new device. The data obtained revealed that for fixed stagnation conditions, the maximum critical mass flux occurred with flashing inception located near the pipe exit; while minimum critical mass fluxes occurred with the flashing front located further upstream. Available data since 1970 for both short and long tubes over a wide range of conditions are compared with the model predictions. This includes test section L/D ratios from 25 to 300 and covers a temperature and pressure range of 110 to 280{degrees}C and 0.16 to 6.9 MPa. respectively. The predicted maximum and minimum critical mass fluxes show an excellent agreement with the range observed in the experimental data.
Research Organization:
Nuclear Regulatory Commission, Washington, DC (United States). Div. of Systems Technology; American Nuclear Society, La Grange Park, IL (United States); American Inst. of Chemical Engineers, New York, NY (United States); American Society of Mechanical Engineers, New York, NY (United States); Canadian Nuclear Society, Toronto, ON (Canada); Japan Society of Multiphase Flow, Kyoto (Japan)
OSTI ID:
106995
Report Number(s):
NUREG/CP--0142-Vol.1; CONF-950904--Vol.1; ON: TI95017077; CNN: Grant OGP-0004172
Country of Publication:
United States
Language:
English

Similar Records

Critical flashing flows in nozzles with subcooled inlet conditions
Journal Article · Sun May 01 00:00:00 EDT 1983 · J. Heat Transfer; (United States) · OSTI ID:5958664

An experimental investigation of critical flow rates of subcooled water through short pipes with small diameters
Journal Article · Sat Nov 30 23:00:00 EST 1996 · International Communications in Heat and Mass Transfer · OSTI ID:418045

Study of nonequilibrium flashing of water in a converging-diverging nozzle. Volume 2. Modeling
Technical Report · Mon Jun 01 00:00:00 EDT 1981 · OSTI ID:5145124