Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Design and Assembly of a Telecentric Zoom Lens for the Cygnus X-ray Source

Conference · · Proc. SPIE 8488, Zoom Lenses IV, 84880B
DOI:https://doi.org/10.1117/12.929160· OSTI ID:1063622

Cygnus is a high-energy radiographic x-ray source. The rod-pinch x-ray diode produces a point source measuring 1 mm diameter. The target object is placed 1.5 m from the x-ray source, with a large LYSO scintillator at 2.4 m. Different-sized objects are imploded within a containment vessel. A large pellicle deflects the scintillator light out of the x-ray path into an 11-element zoom lens coupled to a CCD camera. The zoom lens and CCD must be as close as possible to the scintillator to maximize light collection. A telecentric lens design minimizes image blur from a volume source. To maximize the resolution of test objects of different sizes, the scintillator and zoom lens can be translated along the x-ray axis. Zoom lens magnifications are changed when different-sized scintillators and recording cameras are used (50 or 62 mm square format). The LYSO scintillator measures 200 × 200 mm and is 5 mm thick. The scintillator produces blue light peaking at 435 nm, so special lens materials are required. By swapping out one lens element and allowing all lenses to move, the zoom lens can also use a CsI(Tl) scintillator that produces green light centered at 550 nm. All lenses are coated with anti-reflective coating for both wavelength bands. Two sets of doublets, the stop, and the CCD camera move during zoom operations. One doublet has XY compensation. The first three lenses use fused silica for radiation damage control. The 60 lb of glass inside the 340 lb mechanical structure is oriented vertically.

Research Organization:
Nevada Test Site/National Security Technologies, LLC (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
DOE Contract Number:
AC52-06NA25946
OSTI ID:
1063622
Report Number(s):
DOE/NV/25946--1571
Journal Information:
Proc. SPIE 8488, Zoom Lenses IV, 84880B, Journal Name: Proc. SPIE 8488, Zoom Lenses IV, 84880B Vol. 8488
Country of Publication:
United States
Language:
English

Similar Records

Telecentric Zoom Lens Designed for the Cygnus X-Ray Source
Conference · Mon Jul 01 00:00:00 EDT 2013 · Proceedings of 2013 19th IEEE Pulsed Power Conference (PPC) · OSTI ID:1136330

Alignment and Testing of a Telecentric Zoom Lens Used for the Cygnus X-ray Source
Conference · Sun Sep 01 00:00:00 EDT 2013 · Proc. SPIE 8844, Optical System Alignment, Tolerancing, and Verification VII · OSTI ID:1136418

Assembly and testing of a large zoom lens for proton radiography
Conference · Wed Sep 19 00:00:00 EDT 2018 · Proceedings Volume 10747, Optical System Alignment, Tolerancing, and Verification · OSTI ID:1499704