Technical Basis for DOE Standard 3013 Equivalency Supporting Reduced Temperature Stabilization of Oxalate-Derived Plutonium Dioxide Produced by the HB-Line Facility at Savannah River Site

Technical Report ·
DOI:https://doi.org/10.2172/1063206· OSTI ID:1063206
 [1];  [1];  [1];  [1]
  1. Savannah River National Laboratory (SRNL), Aiken, SC (United States)
This report documents the technical basis for determining that stabilizing highpurity PuO2 derived from oxalate precipitation at the SRS HB-Line facility at a minimum of 625 °C for at least four hours in an oxidizing atmosphere is equivalent to stabilizing at a minimum of 950 °C for at least two hours as regards meeting the objectives of stabilization defined by DOE-STD-3013 if the material is handled in a way to prevent excessive absorption of water.