Capacitive fundamental power coupler and pickup for the 56 MHz SRF cavity

Technical Report ·
DOI:https://doi.org/10.2172/1061905· OSTI ID:1061905
 [1];  [1]
  1. Brookhaven National Laboratory (BNL), Upton, NY (United States)
The beam excited 56 MHz SRF cavity will have a power coupler for a fast frequency tuner. The calculation shows the coupling of the power coupler, βopt, is around 50. Size and location of the power coupler are determined by measurements. Measurements are in good agreement with the simulation results. The axial location of the power coupler for the Nb cavity is limited by corrugations made on the cavity outer conductor for purpose of removing any multipacting. The preferred axial location is 14.5 cm away from the cavity gap start where a slow tuner plate will be. MWS simulations are done to determine the length of the power coupler inner conductor and pickup probe for the Nb cavity at the fixed axial location. Size and location of both the fundamental power coupler and the pickup probe can be decided from the simulation results.
Research Organization:
Brookhaven National Laboratory (BNL), Upton, NY (United States). Relativistic Heavy Ion Collider (RHIC)
Sponsoring Organization:
USDOE Office of Science (SC)
DOE Contract Number:
AC02-98CH10886
OSTI ID:
1061905
Report Number(s):
BNL--99464-2013-IR; KB0202011
Country of Publication:
United States
Language:
English

Similar Records

Capacitive Fundamental Power Coupler and Pickup for the 56 MHz SRF Cavity
Technical Report · Tue Jul 01 00:00:00 EDT 2008 · OSTI ID:939983

The fundamental power coupler and pick-up of the 56 MHz SRF cavity for RHIC
Conference · Mon Mar 28 00:00:00 EDT 2011 · OSTI ID:1020919

3D simulations of multipacting in the 56 MHz SRF cavity
Conference · Sun May 20 00:00:00 EDT 2012 · OSTI ID:1046986