Drums of uranium waste should be disposed of in an economical and environmentally sound manner. The most accurate possible assays of the uranium masses in the drums are required for proper disposal. The accuracies of assays from a shuffler are affected by the type of matrix material in the drums. Non-hydrogenous matrices have little effect on neutron transport and accuracies are very good. If self-shielding is known to be a minor problem, good accuracies are also obtained with hydrogenous matrices when a polyethylene sleeve is placed around the drums. But for those cases where self-shielding may be a problem, matrices are hydrogenous, and uranium distributions are non-uniform throughout the drums, the accuracies are degraded. They can be greatly improved by determining the distributions of the uranium and then applying correction factors based on the distributions. This paper describes a technique for determining uranium distributions by using the neutron count rates in detector banks around the waste drum and solving a set of overdetermined linear equations. Other approaches were studied to determine the distributions and are described briefly. Implementation of this correction is anticipated on an existing shuffler next year.
- Research Organization:
- Los Alamos National Lab., NM (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 105891
- Report Number(s):
- LA-UR--95-1805; CONF-950787--55; ON: DE95015312
- Country of Publication:
- United States
- Language:
- English
Similar Records
Implementing a technique to improve the accuracy of shuffler assays of waste drums
Techniques for improving shuffler assay results for 55-gallon waste drums
Comparison of shuffler and differential die-away technique instruments for the assay of fissile materials in 55-gallon waste drums
Conference
·
Mon Jul 01 00:00:00 EDT 1996
·
OSTI ID:273741
Techniques for improving shuffler assay results for 55-gallon waste drums
Conference
·
Mon Aug 01 00:00:00 EDT 1994
·
OSTI ID:10171027
Comparison of shuffler and differential die-away technique instruments for the assay of fissile materials in 55-gallon waste drums
Journal Article
·
Fri Jul 01 00:00:00 EDT 1994
· JNMM (Journal of the Institute of Nuclear Materials Management); (United States)
·
OSTI ID:7192344