Intermediate-break LOCA analyses for the AP600 design

Technical Report ·
DOI:https://doi.org/10.2172/105674· OSTI ID:105674
A postulated double-ended guillotine break of a direct-vessel-injection line in an AP600 plant has been analyzed. This event is characterized as an intermediate break loss-of-coolant accident (IBLOCA). Most of the insights regarding the response of the AP600 safety systems to the postulated accident are derived from calculations performed with the TRAC-PFl/MOD2 code. However, complementary insights derived from a scaled experiment conducted in the ROSA facility, as well as insights based upon calculations by other codes, are also presented. The key processes occurring in an AP600 during a IBLOCA are primary coolant system depressurization, inventory depletion, inventory replacement via emergency core coolant injection, continuous core cooling, and long-term decay heat rejection to the atmosphere. Based upon the calculated and experimental results, the AP600 will not experience a core heat up and will reach a safe shutdown state using only safety-class equipment. Only the early part of the long-term cooling period initiated by In-containment Refueling Water Storage Tank injection was evaluated Thus, the observation that the core is continuously cooled should be verified for the latter phase of the long-term cooling period, the interval when sump injection and containment cooling processes are important.
Research Organization:
Los Alamos National Lab., NM (United States)
Sponsoring Organization:
Nuclear Regulatory Commission, Washington, DC (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
105674
Report Number(s):
LA-UR--95-1785; ON: DE95015318
Country of Publication:
United States
Language:
English

Similar Records

Analysis of an AP600 intermediate-size loss-of-coolant accident
Technical Report · Fri Sep 01 00:00:00 EDT 1995 · OSTI ID:107770

Analysis of an AP600 intermediate-size loss-of-coolant accident
Conference · Fri Mar 31 23:00:00 EST 1995 · OSTI ID:78592

The LOCA performance of the AP600 passive safety systems
Conference · Tue Dec 31 23:00:00 EST 1991 · Transactions of the American Nuclear Society; (United States) · OSTI ID:6669846