Accurate target-plane focal-spot characterization in high-energy laser systems using phase retrieval
- Laboratory for Laser Energetics, University of Rochester, Rochester, NY
Target-plane intensities on the short-pulse beamlines of OMEGA EP, a petawatt-class laser, are characterized on-shot using the focal-spot diagnostic (FSD), an indirect wavefront-based measurement. Phaseretrieval methods are employed using on-shot and offline camera-based farfield measurements to improve the wavefront measurements and yield more-accurate, repeatable focal-spot predictions. Incorporation of these techniques has improved the mean cross-correlation between the FSD predictions and direct far-field fluence measurements in the target chamber from 0.78 to 0.94.
- Research Organization:
- Univ. of Rochester, NY (United States). Lab. for Laser Energetics
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- FC52-08NA28302
- OSTI ID:
- 1053256
- Report Number(s):
- DOE/NA/28302-1083; 2012-59; 2059
- Journal Information:
- Optics Express, Journal Name: Optics Express Journal Issue: 19 Vol. 20; ISSN 1094-4087
- Publisher:
- Optical Society of America (OSA)
- Country of Publication:
- United States
- Language:
- English
Similar Records
A Focal-Spot Diagnostic for On-Shot Characterization of High-Energy Petawatt Lasers
On-Shot Focal-Spot Characterization Technique Using Phase Retrieval
Journal Article
·
Tue Oct 07 00:00:00 EDT 2008
· Optics Express
·
OSTI ID:939186
On-Shot Focal-Spot Characterization Technique Using Phase Retrieval
Journal Article
·
Wed Sep 10 00:00:00 EDT 2008
· Applied Optics
·
OSTI ID:936866