Key Elements of and Materials Performance Targets for Highly Insulating Window Frames
Journal Article
·
· Energy and Buildings
The thermal performance of windows is important for energy efficient buildings. Windows typically account for about 30-50 percent of the transmission losses though the building envelope, even if their area fraction of the envelope is far less. The reason for this can be found by comparing the thermal transmittance (U-factor) of windows to the U-factor of their opaque counterparts (wall, roof and floor constructions). In well insulated buildings the U-factor of walls, roofs an floors can be between 0.1-0.2 W/(m2K). The best windows have U-values of about 0.7-1.0. It is therefore obvious that the U-factor of windows needs to be reduced, even though looking at the whole energy balance for windows (i.e. solar gains minus transmission losses) makes the picture more complex.In high performance windows the frame design and material use is of utmost importance, as the frame performance is usually the limiting factor for reducing the total window U-factor further. This paper describes simulation studies analyzing the effects on frame and edge-of-glass U-factors of different surface emissivities as well as frame material and spacer conductivities. The goal of this work is to define materials research targets for window frame components that will result in better frame thermal performance than is exhibited by the best products available on the market today.
- Research Organization:
- Ernest Orlando Lawrence Berkeley National Laboratory, Berkeley, CA (US)
- Sponsoring Organization:
- Environmental Energy Technologies Division
- DOE Contract Number:
- AC02-05CH11231
- OSTI ID:
- 1051278
- Report Number(s):
- LBNL-5099E
- Journal Information:
- Energy and Buildings, Journal Name: Energy and Buildings Journal Issue: 10 Vol. 43; ISSN ENEBDR; ISSN 0378-7788
- Country of Publication:
- United States
- Language:
- English
Similar Records
State-of-the-Art Highly Insulating Window Frames - Research and Market Review
Steel-framed buildings: Impacts of wall detail configurations on the whole wall thermal performance
Approach for opaque envelope U-factors for ASHRAE/IESNA 90.1-1989R
Technical Report
·
Sun Dec 31 23:00:00 EST 2006
·
OSTI ID:941673
Steel-framed buildings: Impacts of wall detail configurations on the whole wall thermal performance
Conference
·
Mon Jun 01 00:00:00 EDT 1998
·
OSTI ID:658315
Approach for opaque envelope U-factors for ASHRAE/IESNA 90.1-1989R
Conference
·
Sat Dec 30 23:00:00 EST 1995
·
OSTI ID:211843
Related Subjects
15 GEOTHERMAL ENERGY
29 ENERGY PLANNING, POLICY, AND ECONOMY
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
54 ENVIRONMENTAL SCIENCES
DESIGN
ENERGY BALANCE
FLOORS
Fenestration
window frames
heat transfer modeling
U-factor
thermal transmittance
thermal performance
MARKET
PERFORMANCE
ROOFS
SIMULATION
SPACERS
TARGETS
U VALUES
WALLS
WINDOW FRAMES
WINDOWS
29 ENERGY PLANNING, POLICY, AND ECONOMY
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
54 ENVIRONMENTAL SCIENCES
DESIGN
ENERGY BALANCE
FLOORS
Fenestration
window frames
heat transfer modeling
U-factor
thermal transmittance
thermal performance
MARKET
PERFORMANCE
ROOFS
SIMULATION
SPACERS
TARGETS
U VALUES
WALLS
WINDOW FRAMES
WINDOWS