Verification of VENTSAR
The VENTSAR code is an upgraded and improved version of the VENTX code, which estimates concentrations on or near a building from a release at a nearby location. The code calculates the concentrations either for a given meteorological exceedance probability or for a given stability and wind speed combination. A single building can be modeled which lies in the path of the plume, or a penthouse can be added to the top of the building. Plume rise may also be considered. Release types can be either chemical or radioactive. Downwind concentrations are determined at user-specified incremental distances. This verification report was prepared to demonstrate that VENTSAR is properly executing all algorithms and transferring data. Hand calculations were also performed to ensure proper application of methodologies.
- Research Organization:
- Westinghouse Savannah River Co., Aiken, SC (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC09-89SR18035
- OSTI ID:
- 105111
- Report Number(s):
- WSRC-RP--95-89; ON: DE95017488
- Country of Publication:
- United States
- Language:
- English
Similar Records
VENTSAR V3.0: A Python GUI for Estimating Contaminant Concentrations on or Near Buildings Due to Building Effects and Plume Rise and For Calculating Inhalation and Plume Shine Doses
Verification of VENTSAR XL - a spreadsheet version of VENTSAR
VENTSAR XL User`s Manual
Conference
·
Wed Jul 01 00:00:00 EDT 2020
·
OSTI ID:23027880
Verification of VENTSAR XL - a spreadsheet version of VENTSAR
Technical Report
·
Wed May 01 00:00:00 EDT 1996
·
OSTI ID:405720
VENTSAR XL User`s Manual
Technical Report
·
Wed May 01 00:00:00 EDT 1996
·
OSTI ID:401725