Aerosol tests conducted at Aberdeen Proving Grounds MD

Technical Report ·
DOI:https://doi.org/10.2172/1049475· OSTI ID:1049475
Test data are reported that demonstrate the deposition from a spray dispersion system (Illinois Tool Works inductively charging rotary atomization nozzle) for application of decontamination solution to various surfaces in the passenger cabin of a Boeing 737 aircraft. The decontamination solution (EnviroTru) was tagged with a known concentration of fluorescein permitting determination of both airborne decontaminant concentration and surface deposited decontaminant solution so that the effective deposition rates and surface coverage could be determined and correlated with the amount of material sprayed. Six aerosol dispersion tests were conducted. In each test, aluminum foil deposition coupons were set out throughout the passenger area and the aerosol was dispersed. The aerosol concentration was measured with filter samplers as well as with optical techniques Average aerosol deposition ranged from 3 to 15 grams of decontamination solution per square meter. Some disagreement was observed between various instruments utilizing different measurement principles. These results demonstrate a potentially effective method to disperse decontaminant to interior surfaces of a passenger aircraft.
Research Organization:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC04-94AL85000
OSTI ID:
1049475
Report Number(s):
SAND--2012-4374
Country of Publication:
United States
Language:
English

Similar Records

Decontaminant delivery and application methods to enhance decontamination process and efficacy
Technical Report · Mon Nov 30 23:00:00 EST 2015 · OSTI ID:1233620

Insecticide Exposures on Commercial Aircraft: A Literature Review and Screening Level Assessment
Technical Report · Wed Oct 01 00:00:00 EDT 2008 · OSTI ID:944128

Feasibility Study of Passive Aerosol Sampler for Bio-Agent Detection