Title: Multipacting simulation and test results of BNL 704 MHz SRF gun

Conference ·
OSTI ID:1049264

The BNL 704MHz SRF gun has a grooved choke joint to support the photo-cathode. Due to the distortion of grooves at the choke joint during the BCP for the choke joint, several multipacting barriers showed up when it was tested with Nb cathode stalk at JLab. We built a setup to use the spare large grain SRF cavity to test and condition the multipacting at BNL with various power sources up to 50kW. The test is carried out in three stages: testing the cavity performance without cathode, testing the cavity with the Nb cathode stalk that was used at Jlab, and testing the cavity with a copper cathode stalk that is based on the design for the SRF gun. This paper summarizes the results of multipacting simulation, and presents the large grain cavity test setup and the test results.

Research Organization:
Brookhaven National Laboratory (BNL), Upton, NY (United States)
Sponsoring Organization:
USDOE SC OFFICE OF SCIENCE (SC)
DOE Contract Number:
DE-AC02-98CH10886
OSTI ID:
1049264
Report Number(s):
BNL-96822-2012-CP; R&D Project: KBCH139; 18074; KB0202011; TRN: US1204438
Resource Relation:
Conference: 2012 International Particle Accelerator Conference (IPAC 2012); New Orleans, LA; 20120520 through 20120525