Individual RF Test Results of the Cavities Used in the First US-built ILC-type Cryomodule
Conference
·
OSTI ID:1048036
Eight 1.3-GHz, nine-cell SRF cavities have been installed in a cryomodule intended to demonstrate the ILC design goal of 31.5 MV/m. These cavities all underwent two types of individual RF testing: a low-power continuous-wave test of the 'bare' cavity and a high-power pulsed test of the 'dressed' cavity. Presented here is a discussion of the results from these tests and a comparison of their performance in the two configurations.