Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

LLRF System Upgrade for the SLAC Linac

Conference · · Conf.Proc.C100523:TUPEA061,2010
OSTI ID:1045168
The Linac Coherent Light Source (LCLS) at SLAC is in full user operation and has met the stability goals for stable lasing. The 250pC bunch can be compressed to below 100fS before passing through an undulator. In a new mode of operation a 20pC bunch is compressed to about 10fS. Experimenters are regularly using this shorter X-ray pulse and getting pristine data. The 10fS bunch has timing jitter on the order of 100fS. Physicists are requesting that the RF system achieve better stability to reduce timing jitter. Drifts in the RF system require longitudinal feedbacks to work over large ranges and errors result in reduced performance of the LCLS. A new RF system is being designed to help diagnose and reduce jitter and drift in the SLAC linac.
Research Organization:
SLAC National Accelerator Laboratory (SLAC)
Sponsoring Organization:
US DOE Office of Science (DOE SC)
DOE Contract Number:
AC02-76SF00515
OSTI ID:
1045168
Report Number(s):
SLAC-PUB-15171
Conference Information:
Journal Name: Conf.Proc.C100523:TUPEA061,2010
Country of Publication:
United States
Language:
English

Similar Records

LCLS LLRF Upgrades to the SLAC Linac
Conference · Thu Oct 04 00:00:00 EDT 2007 · Conf.Proc.C070625:2421,2007 · OSTI ID:917259

Linac Coherent Light Source (LCLS) at 2--4 nm using the SLAC linac
Conference · Sun Aug 01 00:00:00 EDT 1993 · OSTI ID:10114933

SLAC Linac RF Performance for LCLS
Technical Report · Thu Aug 24 00:00:00 EDT 2000 · OSTI ID:763854