Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Understanding the importance of the viscosity contrast between the sample solvent plug and the mobile phase and its potential consequences in two-dimensional high-performance liquid chromatography

Journal Article · · Journal of Chromatography A
The effect of solvent viscosity mismatch on elution performance in reversed-phase HPLC was studied using moment analysis. Two conditions were tested: (1) the mobile phase viscosity was less than the injection plug viscosity, and (2) the mobile phase viscosity was greater than the injection plug viscosity. Under the first condition, retention time and elution performance decreased as the viscosity contrast between the mobile phase and injection plug increased. The effect on performance was more marked as the injection volume increased. A decrease in performance of 12% for compounds with retention factors up to 2.8 was apparent even when the viscosity contrast was only 0.165 cP. In the second set of conditions, elution performance was actually observed to increase, by as much as 25% for a 40 {micro}L injection, as the viscosity contrast between the mobile phase and the solute plug increased. No change in the retention factor was observed. This behaviour was attributed to the shape of an injection plug as it enters into the column, whereby a low viscosity plug permeates away from the wall when the column contains a higher viscosity mobile phase, and vice a versa for a high viscosity plug entering a low viscosity mobile phase. At no stage was either a band splitting or shoulders observed with viscosity contrasts up to 1.283 cP, as could have been expected.
Research Organization:
Oak Ridge National Laboratory (ORNL)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-00OR22725
OSTI ID:
1041467
Journal Information:
Journal of Chromatography A, Journal Name: Journal of Chromatography A Journal Issue: 5 Vol. 1216; ISSN 0021-9673; ISSN JOCRAM
Country of Publication:
United States
Language:
English

Similar Records

Solvent viscosity mismatch between the solute plug and the mobile phase: Considerations in the applications of two-dimensional HPLC
Journal Article · Thu Dec 31 23:00:00 EST 2009 · Journal of Chromatography A · OSTI ID:1041469

Visualising the onset of viscous fingering in chromatography columns
Journal Article · Fri Mar 31 23:00:00 EST 2006 · Journal of Chromatography A · OSTI ID:989614

Numerical modeling of elution peak profiles in supercritical fluid chromatography. Part I-Elution of an unretained tracer
Journal Article · Thu Dec 31 23:00:00 EST 2009 · Journal of Chromatography A · OSTI ID:1041474