skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Test Beam Results of a Heavily Irradiated Current Injected Detector (CID)

Journal Article · · Nuclear Instruments and Methods in Physics Research, Section A

A heavily irradiated (3 x 10{sup 15} 1 MeV n{sub eq}/cm{sup 2}) Current Injected Detector (CID) was tested with 225 GeV muon beam at CERN H2 beam line. In the CID concept the current is limited by the space charge. The injected carriers will be trapped by the deep levels and this induces a stable electric field through the entire bulk regardless of the irradiation fluence the detector has been exposed to. The steady-state density of the trapped charge is defined by the balance between the trapping and the emission rates of charge carriers (detrapping). Thus, the amount of charge injection needed for the electric field stabilization depends on the temperature. AC-coupled 16 cm{sup 2} detector was processed on high resistivity n-type magnetic Czochralski silicon, and it had 768 strips, 50 {mu}m pitch, 10 {mu}m strip width and 3.9 cm strip length. The beam test was carried out using a silicon beam telescope that is based on the CMS detector readout prototype components, APV25 readout chips, and eight strip sensors made by Hamamatsu having 60 {mu}m pitch and intermediate strips. The tested CID detector was bonded to the APV25 readout, and it was operated at temperatures ranging from -40 to -53 C. The CID detector irradiated at 3 x 10{sup 15} 1 MeV n{sub eq}/cm{sup 2} fluence shows about 40% relative Charge Collection Efficiency with respect to the non-irradiated reference plane sensors.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
USDOE SC OFFICE OF SCIENCE (SC)
DOE Contract Number:
DE-AC02-98CH10886
OSTI ID:
1040381
Report Number(s):
BNL-91229-2010-JA; NIMAER; KA-04; TRN: US1202415
Journal Information:
Nuclear Instruments and Methods in Physics Research, Section A, Vol. 612, Issue 3; ISSN 0168-9002
Country of Publication:
United States
Language:
English

Similar Records

Modeling, Simulation and Data Fitting of the Charge Injected Diodes (CID) for SLHC Tracking Applications
Journal Article · Tue Oct 27 00:00:00 EDT 2009 · Nuclear Instruments and Methods in Physics Research, Section A · OSTI ID:1040381

Beam test measurements with planar and 3D silicon strip detectors irradiated to sLHC fluences
Journal Article · Sat Jan 01 00:00:00 EST 2011 · IEEE Transactions on Nuclear Science · OSTI ID:1040381

Charge collection study with the ATLAS ITk prototype silicon strip sensors ATLAS17LS
Journal Article · Thu Sep 03 00:00:00 EDT 2020 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1040381