Title: EMITTANCE CONTROL OF A BEAM BY SHAPING THE TRANSVERSE CHARGE DISTRIBUTION, USING A TOMOGRAPHY DIAGNOSTIC.

Conference ·
OSTI ID:10387

A high-brightness beam is very important for many applications. A diagnostic that measures the multi-dimensional phase-space density-distribution of the electron bunch is a must for obtaining such beams. Measurement of a slice emittance has been achieved [1]. Tomographic reconstruction of phase space was suggested [2] and implemented [3,4] using a single quadrupole scan. In the present work we give special attention to the accuracy of the phase space reconstruction and present an analysis using a transport line with nine focusing magnets and techniques to control the optical functions and phases. This diagnostic, coupled with control of the radial charge distribution of presents an opportunity to improve the beam brightness. Combining the slice emittance and tomography diagnostics lead to an unprecedented visualization of phase space distributions in 5 dimensional phase-space and an opportunity to perform high-order emittance corrections.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
USDOE Office of Energy Research (ER) (US)
DOE Contract Number:
AC02-98CH10886
OSTI ID:
10387
Report Number(s):
BNL-65675; KA0403000; R&D Project: LS2; KA0403000; TRN: US0103535
Resource Relation:
Conference: SIXTH EUROPEAN PARTICLE ACCELERATOR CONFERENCE (EPAC), STOCKHOLM (SE), 06/22/1998--06/26/1998; Other Information: PBD: 26 Jun 1998