RESULTS OF STRETCHED WIRE FIELD INTEGRAL MEASUREMENTS ON THE MINI-UNDULATOR MAGNET-COMPARISON OF RESULTS OBTAINED FROM CIRCULAR AND TRANSLATIONAL MOTION OF THE INTEGRATING WIRE.
- BROOKHAVEN NATIONAL LABORATORY
Measurements of the multipole content of the Mini-Undulator magnet have been made with two different integrating wire techniques. Both measurements used 43 strand Litz wire stretched along the length of the magnet within the magnet gap. In the first technique, the wire motion was purely translational, while in the second technique the wire was moved along a circular path. The induced voltage in the Litz wire was input into a Walker integrator, and the integrator output was analyzed as a function of wire position for determination of the multipole content of the magnetic field. The mini-undulator magnet is a 10 period, 80 mm per period hybrid insertion device. For all the data contained herein the magnet gap was set at 49 mm. In the mini-undulator magnet, the iron poles are 18mm x 32mm x 86mm, and the Samarium Cobalt permanent magnet blocks are 22mm x 21mm x 110mm. For this magnet, which is a shortened prototype for the NSLS Soft X-Ray Undulator Magnet, the undulator parameter K = 0.934 B(Tesla){lambda}(cm), and B(tesla) = 0.534/sinh({pi}Gap/{lambda}). At a gap of 49 mm, the magnetic field is 1590 Gauss. The 43 strand Litz wire is supported on motorized x-y stages at both ends of the magnet, which are controlled by stepping motors through a Labview program. One leg of the wire loop is within the magnet gap, and the other leg is in an essentially field free region. Only the leg of the wire loop within the magnet gap is moved during data acquisition. The Litz wire is tensioned with 11.5 pounds, and is wrapped with a supporting tape which is itself tensioned with 18 pounds through a spring and turnbuckle arrangement. With this setup the sag in the wire over the 72 inch span is less than 0.003 inches, as measured with survey instruments. Photographs of the setup are shown.
- Research Organization:
- Brookhaven National Lab., Upton, NY (US)
- Sponsoring Organization:
- USDOE Office of Energy Research (ER) (US)
- DOE Contract Number:
- AC02-98CH10886
- OSTI ID:
- 10374
- Report Number(s):
- BNL--65605; KC0204011; KC0204011
- Country of Publication:
- United States
- Language:
- English
Similar Records
Results of stretched wire field integral measurements on the mini-undulator magnet -- comparison of results obtained from circular and translational motion of the integrating wire
Magnetic measurements of the NSLS (National Synchrotron Light Source) soft x-ray undulator
Magnetic field measurements of the harmonic generation FEL superconducting undulator at BNL-NSLS
Technical Report
·
Fri May 01 00:00:00 EDT 1998
·
OSTI ID:639797
Magnetic measurements of the NSLS (National Synchrotron Light Source) soft x-ray undulator
Technical Report
·
Sun Jul 01 00:00:00 EDT 1990
·
OSTI ID:6657081
Magnetic field measurements of the harmonic generation FEL superconducting undulator at BNL-NSLS
Conference
·
Fri Dec 30 23:00:00 EST 1994
·
OSTI ID:10121332