Combining Transmission Geometry Laser Ablation and a Non Contact Continuous Flow Surface Sampling Probe/Electrospray Emitter for Mass Spectrometry-Based Chemical Imaging
Journal Article
·
· Rapid Communications in Mass Spectrometry
- ORNL
This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection into a continuous flow surface sampling probe/electrospray emitter for mass spectrometry based chemical imaging. The flow probe/emitter device was placed in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collected was immediately aspirated into the probe and on to the electrospray emitter, ionized and detected with the mass spectrometer. Freehand drawn ink lines and letters and an inked fingerprint on microscope slides were analyzed. The circular laser ablation area was about 210 m in diameter and under the conditions used in these experiments the spatial resolution, as determined by the size of the surface features distinguished in the chemical images, was about 100 m.
- Research Organization:
- Oak Ridge National Laboratory (ORNL)
- Sponsoring Organization:
- SC USDOE - Office of Science (SC)
- DOE Contract Number:
- AC05-00OR22725
- OSTI ID:
- 1032812
- Journal Information:
- Rapid Communications in Mass Spectrometry, Journal Name: Rapid Communications in Mass Spectrometry Journal Issue: 24 Vol. 25; ISSN RCMSEF; ISSN 0951-4198
- Country of Publication:
- United States
- Language:
- English
Similar Records
Transmission Geometry Laser Ablation into a Non-Contact Liquid Vortex Capture Probe for Mass Spectrometry Imaging
Laser Ablation Sampling of Materials Directly into the Formed Liquid Microjunction of a Continuous Flow Surface Sampling Probe/Electrospray Ionization Emitter for Mass Spectral Analysis and Imaging
Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry
Journal Article
·
Tue Dec 31 23:00:00 EST 2013
· Rapid Communications in Mass Spectrometry
·
OSTI ID:1185471
Laser Ablation Sampling of Materials Directly into the Formed Liquid Microjunction of a Continuous Flow Surface Sampling Probe/Electrospray Ionization Emitter for Mass Spectral Analysis and Imaging
Journal Article
·
Mon Dec 31 23:00:00 EST 2012
· Analytical Chemistry
·
OSTI ID:1114265
Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry
Journal Article
·
Fri Dec 31 23:00:00 EST 2010
· Analytical Chemistry
·
OSTI ID:1081706