Analysis of Rotary Bayonets and Piping
This report quantifies certain characteristics of the rotary bayonets and associated platform piping on the DO detector. The Vacuum Jacketed 4-inch x 6-inch and 1.5-inch x 3-inch and the 4-inch and 6-inch vacuum pipe articulating jumpers are considered here. The values of greatest importance are the forces required at the bayonet moment arms given in Table II and the stresses summarized in Table III. The forces required should be noted and checked that they are acceptable to the problem. The maximum bending stresses of the vacuum pipes do not exceed 1000 psi and are essentially negligible. The 4-inch x 6-inch vacuum jacketed line experiences the maximum bending stress of 10,300 psi. According to code B31.1, the maximum allowable bending stress is 25,500 psi. The major sources of error in these calculations should be summarized. First, all weights used were approximations and all lengths used were scaled from drawings. Second, while the FRAME MAC{trademark} models resemble the vacuum pipe articulating jumpers, they are definitely simplified. For instance, they do not account for the different stiffnesses of the unions. Finally, the bayonets in the ANSYS models consist of an outer jacket and an inner pipe fixed together at the end of the male sleeve. The actual bayonets are more complex and are composed of various sizes of tubes and pipes which affect the stiffness of the section.
- Research Organization:
- Fermi National Accelerator Laboratory (FNAL), Batavia, IL
- Sponsoring Organization:
- DOE Office of Science
- DOE Contract Number:
- AC02-07CH11359
- OSTI ID:
- 1031180
- Report Number(s):
- FERMILAB-D0-EN-172
- Country of Publication:
- United States
- Language:
- English
Similar Records
Rotary bayonets for cryogenic and vacuum service
Rotary bayonets for cryogenic and vacuum service
D-Zero End Cap Calorimeter Annular Piping Analysis
Conference
·
Fri Dec 30 23:00:00 EST 1994
·
OSTI ID:45494
Rotary bayonets for cryogenic and vacuum service
Conference
·
Thu Jul 01 00:00:00 EDT 1993
·
OSTI ID:10183475
D-Zero End Cap Calorimeter Annular Piping Analysis
Technical Report
·
Mon Aug 22 00:00:00 EDT 1988
·
OSTI ID:1031177