The D0 endcap calorimeter outer hadronic (OH) modules play a major structural role in the calorimeter assembly. The disrete modules, once connected together, form a ring within which other massive calorimetry will reside. It has been proposed that the connection of the OH at the downstream end be accomplished by extending the downstream endplates in the radial direction to form 'ears', and then through-bolting between adjacent ears as shown in Fig. 1. A single 2 1/4 in. dia. bolt is used, and previous calculations have determined that the design load on this joint should be 130,000 lbs tension. The high load and serious consequences of failure make this a critical component in the calorimeter assembly. The purpose of this analysis is to investigate the stresses in the connection and other mechanical characteristics which determine joint performance.