Comparative Study of Vented vs. Unvented Crawlspaces
- ORNL
There has been a significant amount of research in the area of building energy efficiency and durability. However, well-documented quantitative information on the impact of crawlspaces on the performance of residential structures is lacking. The objective of this study was to evaluate and compare the effects of two crawlspace strategies on the whole-house performance of a pair of houses in a mixed humid climate. These houses were built with advanced envelope systems to provide energy savings of 50% or more compared to traditional 2010 new construction. One crawlspace contains insulated walls and is sealed and semi-conditioned. The other is a traditional vented crawlspace with insulation in the crawlspace ceiling. The vented (traditional) crawlspace contains fiberglass batts installed in the floor chase cavities above the crawl, while the sealed and insulated crawlspace contains foil-faced polyisocyanurate foam insulation on the interior side of the masonry walls. Various sensors to measure temperatures, heat flux through crawlspace walls and ceiling, and relative humidity were installed in the two crawlspaces. Data from these sensors have been analyzed to compare the performance of the two crawlspace designs. The analysis results indicated that the sealed and insulated crawlspace design is better than the traditional vented crawlspace in the mixed humid climate.
- Research Organization:
- Oak Ridge National Laboratory (ORNL); Building Technologies Research and Integration Center
- Sponsoring Organization:
- EE USDOE - Office of Energy Efficiency and Renewable Energy (EE)
- DOE Contract Number:
- AC05-00OR22725
- OSTI ID:
- 1029224
- Report Number(s):
- ORNL/TM-2011/438; BT0101000; RABT002
- Country of Publication:
- United States
- Language:
- English
Similar Records
DOE ZERH Case Study: Addison Homes, Cobbler Lane, Simpsonville, SC
A Field Study Comparison of the Energy and Moisture Performance Characteristics of Ventilated Versus Sealed Crawl Spaces in the South
Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting
Program Document
·
Tue Sep 01 00:00:00 EDT 2015
·
OSTI ID:1223622
A Field Study Comparison of the Energy and Moisture Performance Characteristics of Ventilated Versus Sealed Crawl Spaces in the South
Technical Report
·
Wed Jun 22 00:00:00 EDT 2005
·
OSTI ID:850459
Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting
Dataset
·
Wed Apr 27 00:00:00 EDT 2016
·
OSTI ID:2204220