Measurements of Transverse Beam Diffusion Rates in the Fermilab Tevatron Collider
Conference
·
OSTI ID:1027234
The transverse beam diffusion rate vs. particle oscillation amplitude was measured in the Tevatron using collimator scans. All collimator jaws except one were retracted. As the jaw of interest was moved in small steps, the local shower rates were recorded as a function of time. By using a diffusion model, the time evolution of losses could be related to the diffusion rate at the collimator position. Preliminary results of these measurements are presented.
- Research Organization:
- Fermi National Accelerator Laboratory (FNAL), Batavia, IL
- Sponsoring Organization:
- DOE Office of Science
- DOE Contract Number:
- AC02-07CH11359
- OSTI ID:
- 1027234
- Report Number(s):
- FERMILAB-CONF-11-411-AD-APC
- Country of Publication:
- United States
- Language:
- English
Similar Records
Measurements of beam halo diffusion and population density in the Tevatron and in the Large Hadron Collider
Bunch-by-bunch measurement of transverse coherent beam-beam modes in the Fermilab Tevatron collider
Numerical Simulations of Transverse Beam Diffusion Enhancement by the Use of Electron Lens in the Tevatron Collider
Conference
·
Sat Feb 28 23:00:00 EST 2015
·
OSTI ID:1327271
Bunch-by-bunch measurement of transverse coherent beam-beam modes in the Fermilab Tevatron collider
Journal Article
·
Fri Apr 01 00:00:00 EDT 2011
· Phys.Rev.ST Accel.Beams
·
OSTI ID:1967405
Numerical Simulations of Transverse Beam Diffusion Enhancement by the Use of Electron Lens in the Tevatron Collider
Conference
·
Tue May 01 00:00:00 EDT 2012
· Conf.Proc.C1205201:1113-1115,2012
·
OSTI ID:1048428