Portable neon purification system
This paper describes the principle design features of a portable neon purification system and the results of the system performance testing. Neon gas replaces air in the Ring Imaging Cherenkov detector without using vacuum, in experiment E781(SELEX) at Fermilab. The portable neon purification system purifies neon gas by, first purging air with CO{sub 2}, freezing the CO{sub 2}, then cryoadsorbing the remaining contaminants. The freezer removes carbon dioxide from a neon gas mixture down to a maximum concentration of 500 parts-per-million (ppm). The charcoal bed adsorber removes nitrogen from neon gas down to a maximum concentration of 100 ppm. The original RICH vessel was designed to hold vacuum but its photomultiplier tube plates were not.
- Research Organization:
- Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC02-76CH03000
- OSTI ID:
- 102373
- Report Number(s):
- FNAL/C-95/252-E; CONF-950722-12; ON: DE95017460; TRN: 95:006793
- Resource Relation:
- Conference: CEC/ICMC `95: cryogenic engineering conference and international cryogenic materials conference, Columbus, OH (United States), 17-21 Jul 1995; Other Information: PBD: Aug 1995
- Country of Publication:
- United States
- Language:
- English