Technical Advice and Support for the Joint Integrated Non-Intrusive Inspection (JINII) Program Task 2.2 Transmission Digital Radiography (DR)
The Cargo Advanced Automated Radiography System (CAARS) program aims to utilize advanced radiographic systems to detect radiological and nuclear threats. Validation of initial design and testing concepts is a precondition for prototype system development and large-scale deployment. As expected, Depleted Uranium (DU) is a valid surrogate for Special Nuclear Materials (SNM) in CAARS Advanced Technology Demonstration (ATD) performance field-tests of transmission radiography systems. Dual-energy transmission measurements of DU are nearly identical to SNM, and are distinct from lower Z materials, provided the samples are matched to equal areal density. Results from an alternative method, using samples of equal thickness, showed sample discrimination by material density, rather than by atomic number (Z). The transmission measurements of DU and SNM were made with equipment that is nearly identical to current field systems. X-ray source beams at endpoint energies of 5.4 MeV and 9.6 MeV were used to measure transmission through the selected sample materials. The ratio of the x-ray linear attenuation coefficient times length ({micro}L) at 5.4 MeV, to {micro}L at 9.6 MeV is a metric for atomic number based discrimination of materials. The measured ratios were compared with computed values based on LLNL photon cross section data and LLNL developed models of x-ray detector characteristics. Measured ratios for DU differed from HEU by an average of 0.25%, and from WGPu by 0.08%, which is within the noise level of 0.4 to 0.5%. For comparison, measured ratios for Sn differed from HEU by 3.2%, and from WGPu by 3.6%, well beyond the measurement noise. Measured ratios for W differed from HEU by 0.01%, and from WGPu by 0.32%. The measured ratio values presented in Table 1 demonstrate the feasibility of using a threshold ratio to discriminate low-Z (Z < 72) from high-Z (Z {ge} 72) materials (as defined by CAARS specification). In the case of our test system, a threshold ratio of 1.08 would be suitable based on the measured results.
- Research Organization:
- Lawrence Livermore National Laboratory (LLNL), Livermore, CA
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 1022925
- Report Number(s):
- LLNL-TR-473131
- Country of Publication:
- United States
- Language:
- English
Similar Records
Photofission Validation Measurements for Active Interrogation Standards
Fast-neutron/gamma-ray radiography using a broad-energy neutron source
Source term characterization for SNM pit storage facilities
Technical Report
·
Mon Apr 01 00:00:00 EDT 2019
·
OSTI ID:1989462
Fast-neutron/gamma-ray radiography using a broad-energy neutron source
Journal Article
·
Mon Nov 07 19:00:00 EST 2022
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
·
OSTI ID:1901663
Source term characterization for SNM pit storage facilities
Conference
·
Sun Jul 01 00:00:00 EDT 2012
·
OSTI ID:22105900