Title: Global Evaluation of Prompt Dose Rates in ITER Using Hybrid Monte Carlo/Deterministic Techniques

Journal Article · · Fusion Science and Technology
OSTI ID:1020796

The hybrid Monte Carlo (MC)/deterministic techniques - Consistent Adjoint Driven Importance Sampling (CADIS) and Forward Weighted CADIS (FW-CADIS) - enable the full 3-D modeling of very large and complicated geometries. The ability of performing global MC calculations for nuclear parameters throughout the entire ITER reactor was demonstrated. The 2 m biological shield (bioshield) reduces the total prompt operational dose by six orders of magnitude. The divertor cryo-pump port results in a peaking factor of 120 in the prompt operational dose rate behind the bioshield by a factor of 47. The peak values of the prompt dose rates at the back surface of the bioshield were 240 uSv/hr and 94 uSv/hr corresponding to the regions behind the divertor cryo-pump port and the equatorial port, respectively.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
DE-AC05-00OR22725
OSTI ID:
1020796
Journal Information:
Fusion Science and Technology, Vol. 60, Issue 2
Country of Publication:
United States
Language:
English