Neutron counting and gamma spectroscopy with PVT detectors.
Radiation portals normally incorporate a dedicated neutron counter and a gamma-ray detector with at least some spectroscopic capability. This paper describes the design and presents characterization data for a detection system called PVT-NG, which uses large polyvinyl toluene (PVT) detectors to monitor both types of radiation. The detector material is surrounded by polyvinyl chloride (PVC), which emits high-energy gamma rays following neutron capture reactions. Assessments based on high-energy gamma rays are well suited for the detection of neutron sources, particularly in border security applications, because few isotopes in the normal stream of commerce have significant gamma ray yields above 3 MeV. Therefore, an increased count rate for high-energy gamma rays is a strong indicator for the presence of a neutron source. The sensitivity of the PVT-NG sensor to bare {sup 252}Cf is 1.9 counts per second per nanogram (cps/ng) and the sensitivity for {sup 252}Cf surrounded by 2.5 cm of polyethylene is 2.3 cps/ng. The PVT-NG sensor is a proof-of-principal sensor that was not fully optimized. The neutron detector sensitivity could be improved, for instance, by using additional moderator. The PVT-NG detectors and associated electronics are designed to provide improved resolution, gain stability, and performance at high-count rates relative to PVT detectors in typical radiation portals. As well as addressing the needs for neutron detection, these characteristics are also desirable for analysis of the gamma-ray spectra. Accurate isotope identification results were obtained despite the common impression that the absence of photopeaks makes data collected by PVT detectors unsuitable for spectroscopic analysis. The PVT detectors in the PVT-NG unit are used for both gamma-ray and neutron detection, so the sensitive volume exceeds the volume of the detection elements in portals that use dedicated components to detect each type of radiation.
- Research Organization:
- Sandia National Laboratories
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 1020503
- Report Number(s):
- SAND2011-4361
- Country of Publication:
- United States
- Language:
- English
Similar Records
PVT Analysis With A Deconvolution Algorithm
The use of artificial neural networks in PVT-based radiation portal monitors
Related Subjects
73 NUCLEAR PHYSICS AND RADIATION PHYSICS
CAPTURE
DETECTION
GAMMA SPECTROSCOPY
MONITORS
NEUTRON DETECTION
NEUTRON DETECTORS
NEUTRON REACTIONS
NEUTRON SOURCES
NEUTRONS
POLYETHYLENES
POLYVINYLS
PVC
RADIATIONS
RESOLUTION
SECURITY
SENSITIVITY
SENSORS
SPECTRA
STABILITY
TOLUENE
TRADE