Recommendations for erosion-corrosion allowance for Multi-Function Waste Tank Facility tanks
Conference
·
OSTI ID:10194440
- Westinghouse Hanford Co., Richland, WA (United States)
- ChemMet, Ltd., West Richland, WA (United States)
The Multi-Function Waste Tank Facility carbon steel tanks will contain mixer pumps that circulate the waste. On the basis of flow characteristics of the system and data from the literature, an erosion allowance of 0.075 mm/y (3 mil/year) was recommended for the tank bottoms, in addition to the 0.025 mm/y (1 mil/year) general corrosion allowance.