Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Piezoelectric response of precisely poled PVDF to shock compression greater than 10 GPa

Conference ·
OSTI ID:10191987
;  [1]; ; ;  [2];  [3]
  1. Institut Franco-Allemand de Recherches de Saint-Louis, 68 (France)
  2. Sandia National Labs., Albuquerque, NM (United States)
  3. Ktech Corp., Albuquerque, NM (United States)

Prior work has shown that the piezoelectric response of shock-compressed PVDF film prepared with attention to mechanical and electrical processing exhibits precise, well-defined, reproducible behavior to 10 GPa. Higher pressure response continues to pressures approaching 50 GPa, and appears to provide a basis for a very high pressure stress-rate gauge. Previous work shows that differences in response were sometimes observed. The present report describes studies in progress undertaken to increase the precision of the polarization of the PVDF and to develop optimum sensors and shock gauge package designs. Results obtained on such careful prepared PVDF shock gauges show that differences in electrical charge response less than few percent are observed between 10 and 25 GPa.

Research Organization:
Sandia National Labs., Albuquerque, NM (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
10191987
Report Number(s):
SAND--92-2177C; CONF-9208183--1; ON: DE93002469
Country of Publication:
United States
Language:
English