Interim data quality objectives for waste pretreatment and vitrification. Revision 1
The Tank Waste Remediation System (TWRS) is responsible for storing, processing, and immobilizing the Hanford Site tank wastes. Characterization information on the tank wastes is needed so that safety concerns can be addressed, and retrieval, pretreatment, and immobilization processes can be designed, permitted, and implemented. This document describes the near-term tank waste sampling and characterization needs of the Pretreatment, High-Level Waste (HLW) Disposal, and Low-Level Waste (LLW) Disposal Programs to support the TWRS disposal mission. The final DQO (Data Quality Objective) will define specific waste tanks to be sampled, sample timing requirements, an appropriate analytical scheme, and a list of required analytes. This interim DQO, however, focuses primarily on the required analytes since the tanks to be sampled in FY 1994 and early FY 1995 are being driven most heavily by other considerations, particularly safety. The major objective of this Interim DQO is to provide guidance for tank waste characterization requirements for samples taken before completion of the final DQO. The characterization data needs defined herein will support the final DQO to help perform the following: Support the TWRS technical strategy by identification of the chemical and physical composition of the waste in the tanks and Guide development efforts to define waste pretreatment processes, which will in turn define HLW and LLW feed to vitrification processes.
- Research Organization:
- Westinghouse Hanford Co., Richland, WA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC06-87RL10930
- OSTI ID:
- 10189583
- Report Number(s):
- WHC-SD-WM-DQO--011-Rev.1; ON: DE95001570; BR: 35AF11201/35AF11202
- Country of Publication:
- United States
- Language:
- English
Similar Records
High-level waste melter alternatives assessment report
Tank Waste Remediation System tank waste pretreatment and vitrification process development testing requirements assessment
Permitting plan for the immobilized low-activity waste project
Technical Report
·
Tue Jan 31 23:00:00 EST 1995
·
OSTI ID:10123071
Tank Waste Remediation System tank waste pretreatment and vitrification process development testing requirements assessment
Technical Report
·
Mon Oct 24 00:00:00 EDT 1994
·
OSTI ID:10108493
Permitting plan for the immobilized low-activity waste project
Technical Report
·
Thu Sep 04 00:00:00 EDT 1997
·
OSTI ID:341247
Related Subjects
052000
054000
11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES
CHEMICAL ANALYSIS
HANFORD RESERVATION
HEALTH AND SAFETY
HIGH-LEVEL RADIOACTIVE WASTES
LOW-LEVEL RADIOACTIVE WASTES
PLANNING
RADIOACTIVE WASTE DISPOSAL
RADIOACTIVE WASTE PROCESSING
RADIOACTIVE WASTES
REMEDIAL ACTION
SAMPLING
STORAGE FACILITIES
TANKS
WASTE MANAGEMENT
054000
11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES
CHEMICAL ANALYSIS
HANFORD RESERVATION
HEALTH AND SAFETY
HIGH-LEVEL RADIOACTIVE WASTES
LOW-LEVEL RADIOACTIVE WASTES
PLANNING
RADIOACTIVE WASTE DISPOSAL
RADIOACTIVE WASTE PROCESSING
RADIOACTIVE WASTES
REMEDIAL ACTION
SAMPLING
STORAGE FACILITIES
TANKS
WASTE MANAGEMENT