An evaluation of the fire barrier system thermo-lag 330-1
- Sandia National Labs., Albuquerque, NM (United States). Components and Structures Safety and Reliability
- Science and Engineering Associates, Albuquerque, NM (United States)
This report presents the results of three fire endurance tests and one ampacity derating test set of the fire barrier system Thermo-Lag 330-1 Subliming Coating. Each test was performed using cable tray specimens protected by a nominal three-hour fire barrier envelope comprised of two layers of nominal 1/2 inch thick material. The fire barrier systems for two of the three fire endurance test articles and for the ampacity derating test article were installed in accordance with the manufacturer`s installations procedures. The barrier system for the third fire endurance test article was a full reproduction of one of the original manufacturer`s qualification test articles. This final test article included certain installation enhancements not considered typical of current nuclear power plant installations. The primary criteria for fire endurance performance evaluation was based on cable circuit integrity testing. Secondary consideration was also given to the temperature rise limits set forth in the ASTM E119 standard fire barrier test procedure. All three of the fire endurance specimens failed prematurely. Circuit integrity failures for the two fire endurance test articles with procedures-based installations were recorded at approximately 76 and 59 minutes into the exposures for a 6 inch wide and 12 inch wide cable tray respectively. Temperature excursion failures (single point) for these two test articles were noted at approximately 65 and 56 minutes respectively. The first circuit integrity failure for the full reproduction test article was recorded approximately 119 minutes into the exposure, and the first temperature excursion failure for this test article was recorded approximately 110 minutes into the exposure.
- Research Organization:
- Sandia National Labs., Albuquerque, NM (United States)
- Sponsoring Organization:
- Nuclear Regulatory Commission, Washington, DC (United States)
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 10189526
- Report Number(s):
- SAND--94-0146; ON: DE95001508; BR: GB0103012
- Country of Publication:
- United States
- Language:
- English
Similar Records
Fire protection wrapped cable tray ampacity
Ampacity of cables in single covered trays
Fire barrier problems-part 3
Journal Article
·
Thu Nov 30 23:00:00 EST 1989
· IEEE Transactions on Energy Conversion; (USA)
·
OSTI ID:5320682
Ampacity of cables in single covered trays
Journal Article
·
Tue Dec 31 23:00:00 EST 1996
· IEEE Transactions on Power Delivery
·
OSTI ID:477179
Fire barrier problems-part 3
Journal Article
·
Thu Jul 01 00:00:00 EDT 1993
· Nuclear News (La Grange Park, Illinois); (United States)
·
OSTI ID:5677767