Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Bunch length measurements in the SLC damping ring

Conference ·
OSTI ID:10187982
The synchrotron light of the SLC damping ring was used to measure the bunch length with a streak camera at different times in the damping cycle. There are bunch length oscillations after injection, different equilibrium length during the cycle due to rf manipulations to avoid microwave instability oscillations, and just before extraction there is a longitudinal phase space rotation (bunch muncher) to shorten the bunch length. Measurements under these different conditions are presented and compared with BPM pulse height signals. Calibration and adjustment issues and the connection of the streak camera to the SLC control system are also discussed.
Research Organization:
Stanford Linear Accelerator Center, Menlo Park, CA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC03-76SF00515
OSTI ID:
10187982
Report Number(s):
SLAC-PUB--6176; CONF-930511--470; ON: DE93041068
Country of Publication:
United States
Language:
English

Similar Records

Bunch length measurements in the SLC damping ring
Conference · Sun May 16 20:00:00 EDT 1993 · Proceedings of International Conference on Particle Accelerators · OSTI ID:1450115

Pre-compression of bunch length in the SLC damping rings
Conference · Wed Jul 01 00:00:00 EDT 1992 · OSTI ID:10166471

Pre-compression of bunch length in the SLC damping rings
Conference · Wed Jul 01 00:00:00 EDT 1992 · OSTI ID:7115439