Reusability of CaF{sub 2}:Mn TLDS photon irradiations at high absorbed-dose levels

Conference ·
OSTI ID:10181417
The effects of high absorbed dose on the reusability of CaF{sub 2}:Mn thermoluminescence dosimeters (TLDs) are investigated to determine a recommended upper limit on absorbed dose for TLDs that are to be reused. This investigation examines degradation in the uniformity of response and changes in sensitivity of a batch of TLDs when exposed to gamma-radiation doses ranging from 1 Gy to 1000 Gy, and confirms earlier work suggesting that CaF{sub 2}:Mn TLDs should not be reused in applications where cumulative absorbed doses are likely to exceed 100 Gy.
Research Organization:
Los Alamos National Lab., NM (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC04-76DP00789
OSTI ID:
10181417
Report Number(s):
SAND--92-2531C; CONF-930809--4; ON: DE93040049
Country of Publication:
United States
Language:
English

Similar Records

Particle size effect in CaF sub 2 :Mn/teflon TLD response at photon energies from 5-1250 keV
Journal Article · Mon Oct 01 00:00:00 EDT 1990 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (USA) · OSTI ID:6240269

Production and measurement of flash x-ray dose rates in excess of 10 sup 13 rad (CaF sub 2 )/s
Conference · Sat Nov 30 23:00:00 EST 1991 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:5832466

Production and measurement of flash x-ray dose rates in excess of 10 sup 13 rad (CaF sub 2 )/s
Conference · Mon Dec 31 23:00:00 EST 1990 · OSTI ID:5662588