An experiment has been carried out to study impurity generation processes on an inertial limiter on Tore Supra. It is part of a plan to assemble a more detailed integrated picture of impurity generation at the inner wall, the outboard and vertical pump limiters, and the heating and current drive antennas. A system has been implemented to permit quantitative measurement of impurity sources from the outboard limiter in Tore Supra. Data are presented for a representative case in which the limiter is isolated as much as possible from connection with other Tore Supra plasma-facing components. The data are compared with results from the Monte-Carlo SOL impurity transport code BBQ, in an attempt to identify the mechanism for impurity release. Evidence of chemical sputtering as an important impurity source is seen.