21PF overpacks: Phenolic-foam induced corrosion

Conference ·
OSTI ID:10179912

The 21PF overpack was developed in the 1960s and approved for use in the 1970s by the US Department of Transportation (DOT). This package, used for the transport of uranium hexafluoride enriched >1%, has had a history of severe metal corrosion, water ingress, and subsequent leakage. Problems associated with corrosion and water leaking from 21PF overpacks caused the DOT to seek public comments and to undertake rulemaking action. As a result, the DOT required modifications and refurbishment of existing overpacks, and specification changes for the fabrication of new 21PF overpacks. Recent studies conducted by the roofing industry indicate that phenolic foam has caused severe corrosion in metal roofing structures, and its use is being curtailed. These findings need to be explored in order to determine if phenolic foam in 21PF overpacks causes corrosion and compromises the package integrity. Metallic corrosion induced by phenolic foam may affect the continued use of the 21PF overpack because damage to the structural integrity of the metal parts of the packaging will affect its ability to meet design specifications.

Research Organization:
Oak Ridge National Lab., TN (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC05-84OR21400
OSTI ID:
10179912
Report Number(s):
CONF-940748--88; ON: DE94018051
Country of Publication:
United States
Language:
English