Possible water flow rates at DR and H Piles

Technical Report ·
DOI:https://doi.org/10.2172/10179513· OSTI ID:10179513
Estimated water flow rates at H Pile for various postulated conditions are given. The conditions under which the data are valid are as follows: (1) the estimated accuracy of the tube flow rates is {+-}5%, and of pile flow rates {+-}7%; (2) the pile flow rates are based upon the present tube geometry, orifice zone pattern and total flow at H Pile; (3) the flow rates should be increased about 2% if film-free slugs and tubes are considered; and (4) flow rates for enlarged fittings are based upon fittings similar in shape to the present H Pile fittings. The maximum tube flow rates for the DR Pile would be about 2% greater than those given in the table for present tube fittings. For enlarged fittings, the rates for DR Pile tube would be the same as those given for H Pile tubes. The ultimate permissible flow will depend, in part, upon limitations on maximum cross-header pressure and maximum tube inlet pressure, and upon the instrumentation necessary to detect abnormal tube flow conditions.