Design and operation of the NAC-128 spent-fuel storage cask
Technical Report
·
OSTI ID:10177790
- Virginia Power Co., Glen Allen, VA (United States)
Design, licensing and construction of the first of three storage pads for the Surry Power Station Independent Spent Fuel Storage Installation (ISFSI) was completed in 1986 to increase spent fuel storage at the Station. Designed to use large, metal dry storage casks, the Surry Power Station ISFSI will accommodate 84 such casks with a total storage capacity of 811 MTU (1764 spent PWR fuel assemblies). The Surry Power Station ISFSI is located in a wooded area about 1000 meters (3300 feet) east of the reactor facilities. In March 1991, Virginia Power loaded an NAC-I28 storage cask designed, licensed and fabricated by the Nuclear Assurance Corporation. This cask holds 28 spent PWR fuel assemblies and is constructed of stainless steel, lead, and a solid neutron shield material. This is the second cask design used at the Surry Power Station ISFSI.
- Research Organization:
- Electric Power Research Inst., Palo Alto, CA (United States); Virginia Power Co., Glen Allen, VA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC06-76RL01830
- OSTI ID:
- 10177790
- Report Number(s):
- EPRI-TR--101091; PNL--8012; ON: UN93000962
- Country of Publication:
- United States
- Language:
- English
Similar Records
Design and operation of the NAC-128 spent-fuel storage cask
Design and operation of the Westinghouse MC-10 spent-fuel storage cask
An independent spent-fuel storage installation at Surry Station: Design and operation
Technical Report
·
Sat Aug 01 00:00:00 EDT 1992
·
OSTI ID:7016825
Design and operation of the Westinghouse MC-10 spent-fuel storage cask
Technical Report
·
Sun Aug 01 00:00:00 EDT 1993
·
OSTI ID:10178924
An independent spent-fuel storage installation at Surry Station: Design and operation
Technical Report
·
Sat Jul 01 00:00:00 EDT 1989
·
OSTI ID:5853444