Beta measurements and modeling the Tevatron
- Fermilab
The Tevatron collider is now able with two low-{beta} ({beta}*=0.25--0.5m) interaction regions denoted as B0 and D0. This lattice allows independent operation of the interaction regions which required that the previous collider lattice, used in 1988--89, had to be modified. In order to see how well the lattice conforms to the design, measurements of the {beta} function have been carried out at 15 locations in the new Tevatron collider lattice. Agreement can be obtained between the measurements and a computer model for the Tevatron, based on the design, only if the strengths of the gradients in the quadrupoles in the low-{beta} triplet are allowed to differ from their design values. It is also observed that the lattice is very sensitive to the precise values of the gradients in these magnets.
- Research Organization:
- Fermi National Accelerator Laboratory (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- USDOE Office of Science (SC), High Energy Physics (HEP) (SC-25)
- DOE Contract Number:
- AC02-07CH11359
- OSTI ID:
- 10177183
- Report Number(s):
- FERMILAB-CONF-93-173; oai:inspirehep.net:356596
- Journal Information:
- Conf.Proc.C, Journal Name: Conf.Proc.C Vol. 930517
- Country of Publication:
- United States
- Language:
- English