It has been found that warped slugs which produce ``non-seats`` segregated after the centrifuging operation by use of a suitable gauge. The slugs which do not pass the gauge are quenched in water and set aside for later recovery. The purpose of this test was to determine if the rejected slugs could be straightened, degreased and recanned by dipping them directly in the bronze and then through the subsequent steps. One hundred and twenty-nine slugs rejected by the warp gauge were straightened, degreased and recanned by dipping directly into the bronze bath, Eleven non-seats and one Al-Si spill over were rejected at the canning pot.The above procedure is recommended as a possible means of treating slugs rejected in the canning operation because of wrap.