Cycle performance testing of nonazeotropic mixtures of HFC-142a/HCFC-124 and HFC-32/HCFC-124 with enhanced surface heat exchangers
Conference
·
OSTI ID:10162849
In an effort to improve the efficiency of residential heat pumps using altemative refrigerants, two nonazeotropic refrigerant mixtures (NARMs) were tested over a range of heat exchanger capacities to determine their cooling mode performance at US Department of Energy (DOE) heat pump rating conditions of 82{degrees}F (27.8{degrees}C). The two mixtures, 30% HFC-32/70% HCFC-124 and 75% HFC-143a/25% HCFC-124, were selected on the basis of a previous study that screened refrigerant pairs using such factors as boiling point, stability, ozone depletion potential (ODP), and coefficient of performance (COP) to determine suitable candidates for residential heat pump performance. Three refigerant-side heat transfer enhancements were tested to determine improvements to overall system performance. Comparisons were made on the basis of the COP as a function of capacity. The results for one of the heat exchanger combinations, a segmented evaporator and finned condenser, were quite promising. Improvements in COP, relative to that for HCFC-22, were from 9 to 17% for the 30% HFC-32/70% HCFC-124 mixture and from 5 to 9% for the 75% HFC-143a/25% HCFC-124 NARM. Another combination, a smooth tube evaporator with a perforated foil insert and finned condenser, had similar gains at low capacities but experienced decreased performance at the higher capacities. The final combination, a smooth tube evaporator with a perforated foil insert and smooth tube condenser with a benttab insert resulted in poor performance.
- Research Organization:
- Oak Ridge National Lab., TN (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC05-84OR21400;
- OSTI ID:
- 10162849
- Report Number(s):
- CONF-930675-4; ON: DE93015215
- Resource Type:
- Conference paper/presentation
- Conference Information:
- 1993 American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) annual meeting,Denver, CO (United States),26-30 Jun 1993
- Country of Publication:
- United States
- Language:
- English
Similar Records
Cycle performance testing of nonazeotropic mixtures of HFC-142a/HCFC-124 and HFC-32/HCFC-124 with enhanced surface heat exchangers
Thermophysical properties of HCFC-124; An environmentally acceptable refrigerant
Potentially acceptable substitutes for the chlorofluorocarbons: Properties and performance features of HFC-134a, HCFC-123, and HCFC-141b
Conference
·
Fri Jan 01 00:00:00 UTC 1993
·
OSTI ID:6315340
Thermophysical properties of HCFC-124; An environmentally acceptable refrigerant
Conference
·
Mon Jan 01 00:00:00 UTC 1990
· ASHRAE Transactions (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (United States)
·
OSTI ID:5155592
Potentially acceptable substitutes for the chlorofluorocarbons: Properties and performance features of HFC-134a, HCFC-123, and HCFC-141b
Conference
·
Mon May 01 00:00:00 UTC 1989
· International Journal of Thermophysics; (USA)
·
OSTI ID:5568606
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320107
36 MATERIALS SCIENCE
360606
54 ENVIRONMENTAL SCIENCES
540120
AIR POLLUTION ABATEMENT
BUILDING SYSTEMS
CHEMICALS MONITORING AND TRANSPORT
COEFFICIENT OF PERFORMANCE
FLUORINATED ALIPHATIC HYDROCARBONS
HEAT EXCHANGERS
HEAT PUMPS
PERFORMANCE TESTING
PHYSICAL PROPERTIES
REFRIGERANTS
THERMODYNAMIC PROPERTIES
320107
36 MATERIALS SCIENCE
360606
54 ENVIRONMENTAL SCIENCES
540120
AIR POLLUTION ABATEMENT
BUILDING SYSTEMS
CHEMICALS MONITORING AND TRANSPORT
COEFFICIENT OF PERFORMANCE
FLUORINATED ALIPHATIC HYDROCARBONS
HEAT EXCHANGERS
HEAT PUMPS
PERFORMANCE TESTING
PHYSICAL PROPERTIES
REFRIGERANTS
THERMODYNAMIC PROPERTIES